Evaluación clínica de la utilización de placas ortopédicas de contacto limitado (pcl) fabricadas con polipropileno en seis casos de fracturas del esqueleto apendicular del perro
Clinical evaluation of polypropylen plates of limited contact related to fractures from dog's appendicular skeleton
Metadatos
Mostrar el registro completo del ítemResumen
El objetivo del presente trabajo es aportar información sobre el uso de implantes ortopédicos como son las placas de polipropileno de contacto limitado, en fracturas de huesos largos del esqueleto apendicular del perro. Se pretendió verificar el comportamiento mecánico de las mismas y su efecto sobre la callogénesis de las fracturas. Se aplicaron estas placas a 6 perros adultos, de ambos sexos, y de talla mediana (entre 10 y 20 Kg. de peso),que llegaron accidentados a los consultorios externos de la Cátedra de Clínica de pequeños animales de la Facultad de Ciencias Veterinarias (UNLPam).Estos animales presentaron fracturas de tibia (2), húmero (1) y fémur (3). Los implantes ortopédicos aplicados fueron fabricados a partir de tubos de Polipropileno,de 4 mm de espesor de pared.Todos se confeccionaron de un mismo ancho y largo (2 cm x 15 cm),efectuándoseles de cuatro a seis orificios de 4 mm (según las necesidades) para la colocación de tornillos de fijación. Sobre la superficie de contacto con el hueso se realizaron escotaduras para permitir un mínimo contacto entre las placas y el hueso. Se puede concluir que los implantes demostraron ser inertes y no produjeron reacciones adversas que incidan en el estado general del paciente, permitiendo un apoyo temprano del miembro. Se observó además la formación de un callo periostial de gran tamaño This work is about the use of orthopedic implants like polypropylen bone plates of limited contact related mainly to fractures of long bones from dogs appendicular skeleton. Mechanical behavior and effect upon the callogenesis of fractures are also investigated. These bone plates were applied to 6 mature dogs (males and females) of mean height (between 10 and 20 Kg of weight) brought to the external consulting room of Small Animals (Faculty of Veterinary Sciences, UNLPam). The orthopedic implants were manufactured from polypropylen tubes (4 mm wall thickness) and all of them were made of he same width and length (2 cm x 15 cm) with six holes of 4 mm for fixing screws three in each fracture end. Notches were performed on the contact surface with the bone in order to let a minimum rubbing between plates and bones. As a conclusion, the plates of osteosynthesis made of polypropylen are motionless and do not produce adverse reactions that may influence on the patient's general condition, allowing an early limb's support. The formation of a periosteal callus of great size was observed.
Autor/a
Wheeler, Juan Tomás
D'amico, Gladys
Hierro, José
Hagge, Mariana
Lattanzi, Daniela
Schieda, Fernando
Sanfilippo, Susana
Fecha
2001Tipo de documento
artículo
dc.language.iso
spa
En: Ciencia Veterinaria. 2001; vol.3 no.1
Sección: Artículos
Extensión: p. 1-7
Palabras clave
Placas; Polipropileno; Contacto limitado; Fracturas;
Keywords
Plates; Polypropylen; Limited contac; Fractures;
Utilizar el siguiente identificador (URI) para citar o enlazar este registro:
https://repo.unlpam.edu.ar/handle/unlpam/4272Registros en colección
- Ciencia Veterinaria [339]